Battery capacity
Charge used in a match, share of the battery, and runtime at an average current.
Inputs
2:40 in 2026 REBUILT (20 s auto + 2:20 teleop).
%
Lead-acid batteries give far less than rated capacity at high current.
Result
Charge used per match
2.222- Share of usable charge
- 20.58%
- Runtime at this current
- 12.96
- Rated energy
- 216
How it’s calculated
Formula
With your numbers (converted to SI units)
What it means
Rated capacity assumes a slow 20-hour discharge. At FRC currents a lead-acid battery delivers much less (the Peukert effect), so plan with the usable share. A match that uses a large share of the usable charge tends to sag noticeably near the end.
Assumptions
- Constant average current.
- The usable share is an estimate; test your batteries with a load tester.
Learn the concepts behind this on resources.simbotics.org · All formulas